Industry Blog

Uni-Dust Cyclone Case Study


Introduction

A major pharmaceutical company was losing powder from tablet presses and capsule filling machines. This caused a dangerous cocktail of powders to form in the central dust extraction system and was also blocking the expensive HEPA filter at the heart of this system. Having heard of the cyclone, they approached Hanningfield to learn if the innovative dust containment system could benefit them - it could.

 

Our Solution

The cyclone was initially trialled by attaching it to a capsule filling machine, to analyse the effectiveness of the cyclone in capturing a standard pharmaceutical powder - the results were staggering. The filterless cyclone was able to capture over 95% of all excess powder, which is collected in a ‘catch-pot’ at the bottom of the cyclone. This allows the contents to be weighed for batch loss reconciliation, which is excellent for FDA compliance.

The real monetary saving, however, was in protecting the central HEPA filter. Each cyclone has an individual “police” HEPA filter which increases system efficiency to 99.99%, allowing the clean air to flow to the normal dust extraction unit.

As the equipment is designed to be retrofitted to any dust generating plant, process validation is not affected, making it ideal for both new and existing processes.

 

Results and Conclusions

The cyclone was an undoubted success and helped protect the main filter from continual blockage. This was very expensive to replace but required changing every 6
months due to the extreme wear and tear. The cyclone system has saved the central filter to make replacement much more infrequent, saving vast amounts of money and offering an incredible return on investment.

The system also helps protects operators by capturing excess dust in the process room, preventing the formation of a dangerous mix of powders. The customer was extremely pleased with the cyclone and now has more than 40 units installed worldwide.

 

Key Facts

- Capture Over 95% of Excess Dust: The Hanningfield cyclone is capable of capturing most of the dust lost during processing. For this case study, the customer was able to capture and collect over 95% of all powder. In-house trials have achieved results of up to 99.99% efficiency on a pharmaceutical powder.

- Protect Central Dust Extraction: By protecting the central dust extraction system, the customer made vast savings in time, money and improved hygiene, simply by installing the cyclone to their capsule filling machines and tablet presses. This ensured an excellent return on investment (ROI) by protecting the expensive filters in the central dust extraction system.

- Keep Operators Safe: By preventing a dangerous cocktail of powders from forming in the central dust extraction system, operators are kept safe. Instead, dangerous powders are captured in a ‘catch-pot’.

- Comply with FDA Guidelines: Comply with FDA Guidelines; By capturing excess dust in a ‘catch-pot’ the customer was able to undertake batch loss reconciliation, to account for the losses in processing. This is excellent practice and ensures compliance with FDA guidelines.

For more information on the Uni-Dust cyclone, please click here.

Uni-Dust Cyclone in Action

The loss of excess powder from compression and filling machines is one of the major problems in powder processing. Often, powder passing to the central extraction system wil cause downstream filters to block or a dangerous mix of powders to form in the central system itself. If filters blind they can be expensive and time-consuming to replace.

Hanningfield’s solution takes the form of a filterless recovery cyclone - the ‘Uni-Dust’. The cyclone can be fitted (or retrofitted) between the compression/filling machine and the LEV line inside the process room. The cyclone then separates the dense powder particles from the air, allowing clean air to pass down the LEV line and the solid powder material to be collected in a capture-pot at the base of the cyclone, ready for batch loss reconciliation. This capture-pot is also available with a safe-change facility to protect operators.

The Hanningfield Uni-Dust cyclone offers a best-practice solution to the problem of handling excess powder, with typical capture rates of over 95% on most pharmaceutical and food powders.

We are able to offer free trials on your powder at our UK Test Facility. If you are interested in testing your material on our cyclone, simply contact us.

Technical Article: Explosive Dust Control

By Christopher Birch (Technical Sales Engineer, Hanningfield)


Introduction

The control of hazardous and explosive environments and substances is a duty of practically every organisation from manufacturing to education. The dangers associated with flammable, toxic and explosive substances such as wood, solvents or fuels are universally well understood and controls are carefully applied. The management and control of dust is perhaps less well understood despite the critical and catastrophic potential hazard.

Between the years 1980 and 2008, there have been 350 serious dust explosions in US factories killing 133 people and injuring many more. In 2003, in North Carolina, 6 people lost their lives due to a tragic dust explosion at West Pharmaceutical Services.

Dust build up is progressive and often occurs out of plain sight in ceiling voids, on top of machinery or in dust collection systems and their filters. Materials that are not normally considered flammable are often lethal as a dust, this includes most metals and other none flammable solids. In the Pharmaceutical industry the problem is compounded further by a general trend towards NANO scale high potency Active Pharmaceutical Ingredients (API’s) which are extremely toxic and because of their small size can be even more explosive.

Why is dust an explosive hazard?
Dusts have a very large surface area compared to their mass. Burning of solids or liquids can only occur at the surface, where it reacts with oxygen, dust particles are very small but have a high surface area. For example, a 1kg sphere of a material with a density of 1g/cm3 would be about 27 cm across and have a surface area of 0.23 m². However, if that sphere was broken down into spherical dust particles of 50µm in diameter (about the size of flour particles) it would have a surface area of 60 m²!

This greatly increased surface area allows the material to burn much faster, and the extremely small mass of each particle allows it to catch on fire with much less energy than the bulk material as there is no heat loss to conduction within the material. When a dust and air mixture explodes, especially in a confined space such as a silo or warehouse, a significant increase in pressure is created, often more than sufficient to demolish the structure.

There are five necessary conditions for a dust explosion or deflagration:

1. Fuel; presence of a combustible dust.
2. Ignition; there is an ignition source.
3. Dispersion; the dust is suspended in the air at a high concentration (LEL see below).
4. Confinement; the dust is confined.
5. Oxygen; there is an oxidant (typically atmospheric oxygen).

Sources of ignition:

• Electrostatic discharge (common),
• Friction,
• Arcing from machinery or other equipment,
• Hot surfaces, overheated bearings,
• Fire

Mechanism of Dust Explosions
Dust explosions are classified as being either primary or secondary in nature. Primary dust explosions occur inside process plant or similar enclosures and are generally controlled by pressure relief through purpose-built ducting to atmosphere. Secondary dust explosions are the result of dust accumulation inside the factory being disturbed and ignited by the primary explosion, resulting in a much more dangerous uncontrolled explosion inside the workplace. Historically, fatalities from dust explosions have largely been the result of secondary dust explosions.

What is special about dust explosions?

There are a few aspects of dust explosions that make such explosions special. When a flammable dust cloud is created, the dust particles are suspended in air, either because it falls from a height or because a blast of air raises the dust from a surface. Since dust is heavier than air, this will only last as long as the force that created the cloud is present. Some finer particles may remain suspended in air while the larger particles settle. Once settled the dust cloud can be raised again to form another flammable dust cloud.

This is different from gases and vapours that, once dispersed to below the lower flammable limit, cannot form an explosive mixture again.  This capacity to be re-suspended has its most serious consequences when a small explosion whirls up the dust deposits in the plant and then ignites the cloud. These secondary dust explosions are the reason why some plants have been destroyed virtually completely.

Another special aspect of dust explosions is that dust deposits can be ignited, for example, due to self-heating, or because the dust sits on a hot surface. A smouldering or burning dust deposit can be an ignition source for any dust cloud that is generated. Alternatively, the deposit may burn, causing fire damage.

Concentrations
Below a certain value, the Lower Explosive Limit (LEL), there is simply insufficient dust to support the combustion at the rate required for an explosion. A figure 20% lower than the LEL is considered safe. Similarly, if the fuel/air ratio increases above the upper explosive limit there is insufficient oxidant to permit combustion to continue at the necessary rate.

Classifying hazardous areas into zones - HSE Guidance
Once an area has been identified as hazardous it should be classified into zones based on the frequency and persistence of the potentially explosive atmosphere. This then determines the controls needed on potential sources of ignition in that area. These controls apply to fixed and mobile equipment, electrostatic discharges and other sources of ignition that maybe brought into the area, such as matches or lighters.

The international standard, BS EN 61241/3, published in 2002 explains the basic principles of area classification for dust hazards. This standard forms a suitable basis for assessing the extent and type of zone, and can be used as a guide to complying with the requirements of DSEAR. Site specific factors should always be taken into account.

Under ATEX regulations, hazardous areas for explosive dust atmospheres are classified into three zones:

1. Zone 20 is an area in which an explosive atmosphere, in the form of a cloud of combustible dust, is present continuously, for long periods or frequently.
2. Zone 21 is an area in which an explosive atmosphere, in the form of a cloud of combustible dust, is likely to occasionally occur in normal operation.
3. Zone 22 is an area in which an explosive atmosphere, in the form of a cloud of combustible dust, is not likely to occur in normal operation but, if it does occur, will persist for a short period.

On 6 April 2008, the Corporate Manslaughter and Corporate Homicide Act 2007 came into force in the UK, which means companies could face severe fines or even imprisonment should a dust explosion occur.
Marking of equipment.

A standardised scheme is used to identify equipment suitable for a specific area. Equipment will carry the explosion protection symbol “Ex” in a hexagon, the equipment category number (1, 2 or 3), the letter G and or D depending on whether it’s intended for a gas or dust atmosphere and other essential safety information. In many cases this will include a temperature rating expressed as a “T” marking and sometimes a gas group. These indicate limitations to safe use.

Protection and Mitigation from dust explosions
Much research has been carried out in Europe and elsewhere to understand how to control these dangers, but explosions still occur. Increased awareness of the problem and the requirement to perform systematic risk assessments of all operations will lead to identification of hazardous situations and many should be eliminated before an explosion can occur. Good housekeeping practices and operating procedures should be used to prevent the build up of dust.

The alternatives for making processes and plants safer depend on the industry. Some industries exclude air from dust-raising processes, known as “Inerting”. Typically this uses nitrogen, carbon dioxide or argon, which are incombustible gases and thereby inhibit combustion. The same method is also used in large storage tanks where inflammable vapours can accumulate. Usage of oxygen-free gases, however, carries a risk of asphyxiation of the operator.

Other traditional methods are used to accommodate primary dust explosions in process machinery. These include 10 barg explosion arrest valves and sealed, positively pressurised control panels. Increasingly dust extraction is used to protect workers from exposure. Dust filters not only collect all the fine dust from the plant, they also create dust clouds during their cleaning or maintenance, so in effect the problem is simply moved from one location to another.

In the pharmaceutical industry this issue of cleaning and emptying dust collection systems is made more hazardous when a high potency API is present. Cyclones that remove over 95% of the air entrained dust before it reaches the filter are being used as an effective way to control and capture potentially dangerous excess dust. This method of dust control also helps pharmaceutical companies reconcile lost material as is required by cGMP standards.

Summary
Unlike solvents or explosive gasses, dust does not automatically disperse in the natural environment. Unless removed from areas of build up the risk of dust explosion progressively increases.

Avoidance of dust explosions and their catastrophic effect can be achieved by careful adherence to HSE guidelines and ATEX and DSEAR requirements. Good housekeeping practices enforced by well adopted operating procedures should be used to eliminate the build-up of deposits of combustible dust. Organisations should regularly inspect areas where dust can build up unseen.

Extraction and then capture of excess dust, by cyclone, before that dust can build up in dust filtration systems is an effective control measure in line with cGMP standards.


Company Description
Hanningfield Process Systems is a UK manufacturer of powder containment, powder processing and powder handling equipment. Hanningfield’s range of products include vacuum convey systems, milling and crushing machines, lifts and hoists and the unique Uni-Dust cyclone.

Manufactured in stainless steel, the filterless Uni-Dust cyclone is a hygienic method of capturing excess dust in the controlled environment of the process room. The equipment is designed to be retrofitted to any dust generating plant; process validation is not effected, making it ideal for both new and existing processes. In-line with cGMP the Uni-Dust makes loss reconciliation a simple matter.

The cyclone separates the solids from the clean air, capturing at least 95% excess powder in a collection pot, the air is then passed through a “police” HEPA filter which increases system efficiency to 99.99% before the clean rather than contaminated air flows to the normal dust extraction unit.


Chris Birch

About the Author

Chris Birch is a Technical Sales Engineer at Hanningfield, with 14 years experience working in diverse areas including containment, size reduction and material handling.

Chris is extremely familiar with cGMP, ATEX regulations, process validation, calibration and reference standard hierarchy.

E-Mail: chris.birch@hanningfield.com

Hanningfield on Front Page of EPM Magazine

Hanningfield are pleased to be on the front page of the January/February edition of EPM Magazine.  Hanningfield are prominently featured on the front page of the magazine, with an article about the Uni-Dust cyclone, and how it can be used to collect excess tablet press powder.


To see the editorial simply click the image above, or click here.

Capturing Excess Dust from Tablet Compression Machines

Losing excess dust from a tablet press during processing can be a major problem. Usually this excess powder is piped down the LEV line, to the central dust extraction system. This powder will come into contact with various filters during this journey, often causing them to blind. Changing these filters can prove both expensive and time consuming.


The Uni-Dust cyclone is designed to overcome this problem. By placing the cyclone between the tablet press and the LEV line, excess powder can be collected in capture-pot at the foot of the cyclone; this allows batch losses to be reconciled inside the process room itself. Importantly, the Uni-Dust cyclone normally separates over 95%the solids from the air, allowing clean air to pass to the central dust extraction system.

For more information on the Uni-Dust cyclone, please click here.

High Efficiency Cyclones for the Pharmaceutical Industry

The Hanningfield ‘Uni-Dust’ high efficiency cyclone is capable of capturing up to 99.99% of excess dust from pharmaceutical processing.

The high efficiency cyclone is uniquely placed within the process room itself, capturing excess dust in a catch pot.  This prevents excess powder from flowing to the central dust extraction, preventing the blocking of filters, and the expenses that come with changing these filters.

For example. Excess powder from a tablet press or a capsule filling machine can be collected in the process room itself - making batch loss reconciliation simple.

For more information on the ‘Uni-Dust’ high efficiency cyclone, please click here.

Uni-Dust Advert: Manufacturing Chemist

Hanningfield are pleased to announce a full-page advert in October’s ‘Manufacturing Chemist’.

The full-page ad, on page 23 of the magazine, highlights the benefits of the Uni-Dust cyclone to engineers around the world.

To view the advert, just click the image below:

Uni-Dust Advert in Manufacturing Chemist

Dust Containment - Make Your Process Safe

The containment of dust during pharmaceutical, food and chemical processing is vital.

Any excess dust which is not properly captured can enter the working environment and compromise the safety of workers.  Airborne dust particles can be extremely hazarous, hence the containment of this becomes vital.  The Uni-Dust cyclone helps contain this problem, whilst making product reintroduction or batch loss reconciliation possible.

For more information on the issue of dust containment, please click here.

Dust Control in Pharmaceuticals

The control of excess dust in pharmaceutical processing is extremely important.  Wayward dust can become airborne and compromise the safety of the working environment and the validity of other products.

Controlling the excess dust becomes vital, and the Uni-Dust powder recovery cyclone can play a pivotal role in this.  By capturing excess dust before it reaches the central dust extraction system, the filterless cyclone is able to retain waste powder in the process room.  This prevents a dangerous mix of powders from forming in the central filter, making the working environment much safer.  This also helps significantly prolong the life of the filter, which is often difficult and expensive to replace.

To learn how you can capture up to 100% of your excess powder, please click here.

Innovative Powder Cyclone

The Uni-Dust powder recovery cyclone is capable of collecting excess dust from process machinery such as tablet presses or capsule filling machines.

This offers excellent advantages, as captured powder can either be reconciled or even re-used.

For more information on the cyclone, please click here.

Tag Cloud